Reverse Laminar Air Flow in Chennai
Sterile Tech TM India offers reverse laminar airflow systems for powder handling and cleanroom applications. Call 95515 99977 for enquiries.
Looking for Reverse Laminar Air Flow Manufacturers in Chennai? Explore customized airflow and filtration solutions for pharmaceutical, laboratory, and cleanroom applications.
Reverse Laminar Air Flow is an airflow arrangement designed to draw air away from a designated work area through an appropriate filtration and exhaust system. Depending on the application and system configuration, it can help control airborne particles and reduce the risk of contamination spreading into surrounding areas.
These systems are designed according to the process requirements, airflow direction, filtration needs, and applicable cleanroom standards.
Sterile Tech TM India offers reverse laminar air flow systems designed for applications that require controlled airflow during powder handling, dispensing, weighing, and sampling operations. These systems are used in pharmaceutical facilities, chemical processing environments, research laboratories, and other industrial applications where airborne powder and dust need to be controlled.
A reverse laminar air flow system, also known as a reverse flow powder containment booth or powder dispensing booth, uses a designed airflow pattern to draw airborne particles towards the booth’s filtration system. Depending on the configuration, filtered air may be recirculated or partially exhausted to help manage airborne dust during operations.
A reverse laminar air flow system is a specialised airflow enclosure used for selected powder-handling and material-processing activities. Unlike a conventional laminar airflow workbench that generally supplies clean air towards the work area for product protection, a reverse airflow booth is designed to help contain airborne particles generated during activities such as weighing, dispensing, and sampling.
The system’s performance depends on its airflow design, filter arrangement, air balance, booth construction, and the material being handled. Equipment should be selected according to the process hazards and the required level of operator and environmental protection.
Reverse laminar airflow systems are designed differently from conventional laminar airflow workstations. While conventional laminar airflow units primarily protect the product from airborne contamination, reverse laminar airflow booths are commonly designed to help contain dust generated during activities such as weighing, sampling and dispensing pharmaceutical ingredients.
In a typical system, air moves down through the working area and is drawn towards return or exhaust grilles. The airflow arrangement helps direct airborne particles away from the operator’s breathing zone and towards the filtration system. The actual containment performance depends on the booth design, airflow balance, filter arrangement, installation and operating practices.
Sterile Tech TM India offers reverse laminar airflow and powder containment booth solutions for facilities seeking equipment tailored to their operational requirements.
Sterile Tech TM laminar flow cabinets deliver a advanced level of product protection for work in progress. Ergonomic design lessens user fatigue and improves process accuracy. Sterilize air though filter and blow it across work surface as a particle-free laminar air stream.
The Laminar Air Flow provides Product protection from room contaminants but does not protect the Operator
Ambient air first permits through a Pre-filter which traps the larger dust and dirt particles. The blower then directs this pre-filtered air, now under positive pressure, through the 99.99% effectual HEPA(High Efficiency Particular Air) having effectiveness rating as high as 99.99%, thus retaining all air borne particles of size 0.3 micron and larger.
Double filtered air blow in laminar flow through the work area at designed velocity of 90 ft/min +/- 20%. Filter engulfing the perfect work area with sterile, unidirectional ultra-clean air. It also washes away particles that may be generated by Manipulation within the Flow. HEPA filters made of micro clean glass fibre paper of imported origin with fine corrugated aluminium foil separators. Pressure drop will be 18mm WG. Pre -filters are manufactured by using synthetic non woven polyester fabric material with HDPE mesh reinforcement on either back/Top side. The filters are protected by suitable grill arrangement.
Blower Motor Assembly: Statically and dynamically balanced single phase, single/double shaft motor directly connected with centrifugal type aluminium/PVC impeller and enclosed with a specially designed MS casing.
Sterile Tech TM Horizontal Laminar Airflow Hoods offer a HEPA filtered air is passed through the main chamber of the clean work bench in a horizontal laminar air stream and exhausted through from opening. It is ideal for operations requiring a particle-free, bacteria-free, clean air atmosphere. The clean work area provides an excellent work space for small laboratory utilization, microscopes, pipetting, sterile drug preparations, IV admixture preparation, or any application requiring work-in-progress progress from outside potentially harmful contaminants.
| Sterile Tech TM Model Number | SHL 222 | SHL 322 | SHL 422 | SHL 622 |
| Working Size (LxDxH)Ft | 2’x2’x2’ | 3’x2’x2’ | 4’x2’x2’ | 6’x2’x2’ |
| Sterile Tech TM Model Number |
Working Size (LxDxH)Ft |
| SHL 222 | 2’x2’x2’ |
| SHL 322 | 3’x2’x2’ |
| SHL 422 | 4’x2’x2’ |
| SHL 622 | 6’x2’x2’ |
Sterile Tech TM Vertical Flow Hoods are engineered to deliver the ideal particle-free, bacteria-free clean-air environment needed for laboratory work, testing, developed, inspection, or pharmaceutical procedures. Exclusive design innovations provide exceptional performance in the most challenging environments.
In vertical flow models, filtered air is passed through the main work chamber of the clean bench in a vertical laminar (unidirectional) air stream on work surface and is exhausted through the holes of work surface.
| Sterile Tech TM Model Number | SVL 222 | SVL 322 | SVL 422 | SVL 622 |
| Working Size (LxDxH)Ft | 2’x2’x2’ | 3’x2’x2’ | 4’x2’x2’ | 6’x2’x2’ |
| Sterile Tech TM Model Number |
Working Size (LxDxH)Ft |
| SVL 222 | 2’x2’x2’ |
| SVL 322 | 3’x2’x2’ |
| SVL 422 | 4’x2’x2’ |
| SVL 622 | 6’x2’x2’ |
Sterile TechTM Vertical Flow Hoods are engineered to provide the ideal particle-free, bacteria-free clean-air environment needed for laboratory work, testing, manufacturing, inspection, or pharmaceutical procedures. Exclusive design innovations provide exceptional performance in the most demanding environments.
Microbiological manipulations, pathological laboratories, microelectronics, optics, food and beverage, , avionics ,Biotechnology & Toxicology ,Scientific & Industrial Research, Biology, Tissue Culture, Laboratories in Hospitals, Medical Services, Educational Institutions, agriculture, animal husbandry, Drugs & Pharmaceutical Industries, Automotive & Electronics, Space Applications, Sterility testing, Semiconductor manufacturers
| Sterile TechTM Model No | SML 222 | SML 322 | SML 422 | SML 622 | |
| Working Size | (W x D x H)Ft | 2’x2’x2’ | 3’x2’x2’ | 4’x2’x2’ | 6’x2’x2’ |
| Sterile Tech TM Model Number |
Working Size (LxDxH)Ft |
| SML 222 | 2’x2’x2’ |
| SML 322 | 3’x2’x2’ |
| SML 422 | 4’x2’x2’ |
| SML 622 | 6’x2’x2’ |
Used for selected powder dispensing, ingredient weighing, material sampling, and other pharmaceutical processing activities where powder containment is required.
Can support controlled handling of suitable powdered materials, subject to chemical compatibility and risk assessment.
Provides an enclosed working area designed to help manage airborne particles generated while measuring or dispensing powders.
Suitable configurations may support powder sampling, preparation, and weighing during laboratory work.
May be used for selected ingredient-handling activities when the booth is designed for the material and process requirements.
Can support material handling operations that generate dust and airborne particles, depending on the booth’s design and suitability for the application.
Actual containment performance must be established for the specific material and process. Hazardous, toxic, sensitising, or combustible powders may require specialised containment, exhaust treatment, or additional safety measures.
Selecting an experienced manufacturer is essential for obtaining equipment that meets your operational requirements. Before purchasing, consider:
Sterile Tech TM India supplies cleanroom and laboratory equipment, including reverse laminar airflow systems and powder containment booths. Customers can discuss their process requirements and evaluate equipment options according to the intended application.
When enquiring, provide details of the powder or material being handled, the type of operation, required working dimensions, installation location, and any specific containment or exhaust requirements. This information helps establish the appropriate equipment configuration.
Confirm the technical specifications, filtration details, airflow performance, testing documentation, installation scope, and after-sales service arrangements before placing an order.
Get Direction to Sterile Tech, Write a review about Sterile Tech
Looking for reverse laminar air flow equipment for powder dispensing, weighing, sampling, or cleanroom applications?
Contact Sterile Tech TM India to discuss your reverse laminar air flow requirements and request product specifications.
Its purpose is to establish a controlled airflow path that helps manage airborne contamination or contain process-related particles, depending on the system design.
Yes. Dimensions, airflow capacity, filtration arrangements, and construction materials can be selected according to the application and engineering specifications.
These systems may be used in pharmaceutical, biotechnology, laboratory, research, and specialized industrial environments.
The filtration arrangement depends on the process. HEPA filters and suitable prefilters may be incorporated where required. Hazardous or toxic materials may require specialized containment and exhaust treatment.
Share your application, required dimensions, installation location, airflow specifications, and filtration requirements with the manufacturer to obtain a suitable technical proposal and quotation.