Pass Box

Pass Box

We are acquainted with both two kinds of Static and Dynamic Pass Boxes. Those detailed description and requirement are listed below.

  • Static Pass Box

Technical Specification

Cleanliness: class 100, (ISO – 5)

Standard: FED 209E

Velocity: 90FPM±20

Noise Level: 65db max

Power Supply: 230V (1Ø) or 420V (3 Ø), 50Hz

Particle Retention: 0.3 micron

Supply filter: HEPA Filter efficiency 99.99% Down to 0.3µ H-14 Rating.

Pre Filter: Micro glass fibre media of EU-4 Rating

Motor Blower Assembly: Centrifugal Blower statically and dynamically balanced with Suitable Rating

Static Pass Box

Static Pass Box

Dimension Table

Sterile Tech TM Model Number SPB 111(S) SPB 222(S) SPB 332(S) SPB 442(S) SPB 223(S) SPB 333(S) SPB 443(S)
Working Size (WxDxH)Ft 18” x 18” x 18” 2 x 2 x 2 3 x 3 x 2 4 x 4 x 2 2 x 2 x 3 3 x 3 x 3 4 x 4 x 3
Sterile Tech TM
Model Number
Working Size
(LxWxH) Ft
SPB 111(S) 18” x 18” x 18”
SPB 222(S) 2 x 2 x 2
SPB 332(S) 3 x 3 x 2
SPB 442(S) 4 x 4 x 2
SPB 223(S) 2 x 2 x 3
SPB 333(S) 3 x 3 x 3
SPB 443(S) 4 x 4 x 3

Download Catalogue

  • Dynamic Pass Box

Controlling the ingress of particulate corruption into cleanrooms and other controlled environments is paramount in order to preserve the reliability of products and processes. Personnel traffic is the most important factor which must be controlled. Pass Boxes and Transfer Hatches are an actual solution as they allow supplies to be moved into the controlled environment without real personnel movement. They may also be used to defend the external environment from egress of pollution.

Dynamic Pass Box permits process in sterile and particle free circumstances because the continuous flushing of the working area by a unidirectional and vertical and ultra filtered airflow, it assures a full product protection

Technical Specification

Cleanliness: class 100, (ISO – 5)

Standard: FED 209E

Velocity: 90FPM±20

Noise Level: 65db max

Power Supply: 230V, 1Ø, 50Hz
Particle Retention: 0.3 micron

Supply filter: HEPA Filter efficiency 99.99% Down to 0.3µ H-14 Rating.

Pre Filter: Micro glass fibre media of EU-4 Rating
Motor Blower Assembly: Centrifugal Blower statically and dynamically balanced with Suitable Rating

Door lock system: Electro Magnetic Door Interlocking

Dynamic Pass Box

Dynamic Pass Box

Dimension Table

Sterile Tech TM Model Number SPB 111(D) SPB 222(D) SPB 332(D) SPB 442(D) SPB 223(D) SPB 333(D) SPB 443(D)
Working Size (W x D x H)Ft 18” x 18” x 18” 2 x 2 x 2 3 x 3 x 2 4 x 4 x 2 2 x 2 x 3 3 x 3 x 3 4 x 4 x 3
Sterile Tech TM
Model Number
Working Size
(LxWxH) Ft
SPB 111(D) 18” x 18” x 18”
SPB 222(D) 2 x 2 x 2
SPB 332(D) 3 x 3 x 2
SPB 442(D) 4 x 4 x 2
SPB 223(D) 2 x 2 x 3
SPB 333(D) 3 x 3 x 3
SPB 443(D) 4 x 4 x 3